WebMay 3, 2024 · So here is yet another page on how to set up a VFD. VFD grounding question. Here's a link to an automationdirect VFD. Huanyang Vfd Inverter Manual. Huanyang Chinese VFD settings and manual here! 1725rpm, inverter duty, class F VFD = Huanyang HY02D223B Settings pd001 = 1. Huanyang inverter PD settings; Huanyang … WebNov 10, 2024 · The vfd will take that 2.5v and apply that percentage to the max spindle speed it knows, in this example 12000rpm. so you end up with (2.5/10)*12000 = 4000rpm. your max rpm may be different, consult your manual. But that is my guess as to what is happening. In my vfd instructions, setting pd0072 to 400 was like setting the max …
Chinese vfd settings
Did you know?
WebFeb 28, 2024 · Re: A2-8002 VFD set up - any help appreciated. « Reply #2 on: February 28, 2024, 07:57:36 PM ». Most VFD's need a parameter setting to enable external control as they default to the pot and keys on the front. Then you need to set the input parameter for control to PVM or 0-10V or what ever your system outputs then all you should need is to ... WebOct 29, 2016 · Chinese CNC Spindle + Huanyang 3.3KW VFD Test How to set up a Vfd husqvarna Chinese Spindle Driver Did this video help you? Ben Jamin: hello, can you publish the settings of the different pd values. As manual says to reset VFD setting to factory settings PD013 must set to 08, but to my VFD 08 does nothing. 3.3KW (4HP) …
WebJun 17, 2024 · ActonGorton: the output was reading 5.85V. Ok, so you are getting an output signal from the X-controller that should activate the spindle and you have the control signal hooked to the correct inputs on the VFD (VI/ACM), the only thing left is the internal setup of the VFD. I’ve taken you as far as I can. WebThis video shows my setup and test of the spindle and HY VFD. I discuss how to wire the system and how to program the VFD.One note: if it isn't clear, this i...
WebAug 30, 2024 · J1 Jumper may need changing also. PD002=1 These ( 2 )Parameters are for Pot / Manual Speed Control. PD073=1. PD143=2 ( This is the number of motor Poles this has nothing to do with wiring ) The output from the VFD Drive to the spindle is 3Ph so you have 3 Hot wires and a Ground so 4 wires are required. Mactec54. http://montanafreeware.weebly.com/blog/free-download-program-huanyang-chinese-vfd-settings-and-manual-here
WebApr 20, 2024 · its (was) my only chinese vfd, a xin shuang yuan xsy-at1, 2.2 kw, 1-ph in/3-phase out. iv had it for a couple of years, but it was used sparingly. i was running a 1.5 kw motor with a 250mm grinding wheel. after i hit the stop button it threw the 13 amp breaker (230v). no smell. i reset the breaker, connecter the vfd and it did
WebNov 20, 2013 · 3. I just tell you how to set up VFD as following. Firstly, adjust the PD013 to 8 (set the setting to factory setting) Secondly, adjust the PD005 to 400. Thirdly, adjust the PD004 to 400. Finally, adjust the … florida state university business analyticsWebMar 31, 2015 · The way you have wired it looks correct. You should have the incoming single phase power fused or going to a breaker before start-up. You should do basic programming before running the motor, i.e. … great white shark jumping videoWebGo to the ports & pins configuration and select the spindle setup tab. Make sure that the Disable Spindle Relays checkbox is unchecked. We don't want mach3 to output a signal for a relay since the spindle will start up and turn off within the VFD and not from an external relay. Next, go to the HuanyangVFD settings by clicking on Menu -> plugin ... florida state university cake decorationsWebFeb 11, 2024 · in this video i will try to explain as best i can how to program Chinese VFD. all necessary settings to make it run and what these settings actually do.link ... florida state university calendar 2022-23WebJan 19, 2024 · Number of poles: 4. Rated RPM: 24,000. When looking for a VFD for RPM control, it is advised to consider a VFD with an output power of more than the power … florida state university businessWebMay 3, 2024 · Initially Reset the VFD to factory default setting settings by setting F00.28 = 1. (See below on how to change the parameters) To begin programming, press the PRGM/ESC button and the programming parameters will show the parameter menu. With a new VFD out of the box, it will be F00.Press the FUNC/DATA button to enter the F00 … great white shark katharineWebThe configuration settings for our VFD's are these: VFD Setup: Change PD001 to '0' (source of run commands) Change PD003 to 300 (main frequency - Hz) Change PD004 to 300 (base frequency - Hz) Change PD005 to 400 (max operating frequency - Hz) Change PD006 to 2.5 (intermediate frequency - Hz) Change PD008 to 220 (max voltage - V) … great white shark jump videos